Vaillant Fault code Vaillant
L.144

Flame signal too weak at the control electrode

Blocking: it retries by itself

The flame signal measured by the control electrode is too weak, and the boiler could not make up for the wear of this electrode. The appliance switches to emergency mode, with reduced comfort, and the code clears by itself as soon as the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show L.144?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L.144

The meaning depends on the boiler: find yours below.

L.144

The ionisation signal of the monitoring electrode is insufficient

Blocking: it retries by itself VCW CS/1-5, VCW CS/1-7

What our technician checks

  • The whole flue gas path (recirculation, blockage)
  • The condensate drain pipe
  • The dynamic gas pressure (and the external gas pressure switch, if any)
  • The gas type and its setting (D.156 and D.157)
  • The control electrode, replaced if needed
  • The gas valve, to be replaced if faulty
  • The circuit board, to be replaced if faulty
  • The wiring harness and all its connectors

Related codes