Vaillant Fault code Vaillant
F.77

Flue gas flap or condensate pump fault

Breakdown: the boiler is stopped

An accessory connected to the boiler is blocking the burner: the flue gas flap does not confirm its position, or the condensate pump is faulty or overflowing. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.77?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.77

The meaning depends on the boiler: find yours below.

F.077

Burner operation is blocked by a condensate pump or a flue

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.77

Condensate pump or feedback signal from the heating accessory module

Breakdown: the boiler is stopped VCW /3
F.77

Flue damper / condensate pump fault

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7
F.77

Flue gas damper/condensate pump fault

Breakdown: the boiler is stopped VC /4-5, VC 806/5-5, VCC /4, VUW /5-5
F.77

Accessory error (flue gas damper, condensate pump...)

Breakdown: the boiler is stopped VC 486/5-5
F.77

Flue gas damper/fresh air damper error

Breakdown: the boiler is stopped VKK /5
F.77

Flue damper faulty or the flue damper does not send a correct feedback message

Breakdown: the boiler is stopped VUW /3-5
F.77

Flue gas damper error

Breakdown: the boiler is stopped VUW /4-5
F.77

Condensate pump or accessory feedback blocking heating mode

Breakdown: the boiler is stopped VSC /2

The boilers that show this code

What our technician checks

  • The flue gas flap: wiring, feedback switch, correct operation
  • The flue gas flap, replaced if faulty
  • The condensate pump and its electrical connection, replaced if faulty
  • The VR40 accessory cable and the jumper of the 2-of-7 multi-function module
  • The contact thermostat jumper

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.