Water pressure sensor: signal too high
Breakdown: the boiler is stopped
The water pressure sensor sends a signal that is too high or interrupted: cable short-circuited or sensor faulty; on the ecoTEC plus /5-5, ecoTEC pro /5-3 and ecoVIT VKK /4 this code reports a heating water pressure that is too high. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.74?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.74
The meaning depends on the boiler: find yours below.
The signal from the water pressure sensor has been interrupted.
Water pressure sensor signal in incorrect range (too high)
Water pressure sensor fault (signal too high)
Water pressure sensor signal in an unsuitable range (pressure too high)
Water pressure sensor fault
Water pressure sensor signal in an incorrect range (too high)
The boilers that show this code
What our technician checks
- The heating-side water pressure, pump off, draining some water if it is too high
- The sensor wiring harness and plugs (short circuit to 5 V or 24 V)
- The water pressure sensor, replaced if faulty