Invalid boiler identification
Breakdown: the boiler is stopped
The circuit board and the display do not recognise the boiler model: the device identification (DSN) or the coding resistor is missing or does not match, for example after the board and the display were replaced at the same time. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.70?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.70
The meaning depends on the boiler: find yours below.
The appliance reference (DSN) is missing, incorrect or incompatible with the coding resistor.
Appliance variant not valid for the display and/or the electronics
Fault §§ incorrect appliance coding
Invalid appliance identification (DSN)
Invalid appliance reference (DSN)
No valid DSN in AI and/or BMU
The boilers that show this code
What our technician checks
- The device identification (DSN), to be set under d.93
- The power-rating coding resistor
- The wiring harness, between the board and the gas valve
- The control electrode, to be replaced after the board and display were changed together