Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.70

Invalid boiler identification

Breakdown: the boiler is stopped

The circuit board and the display do not recognise the boiler model: the device identification (DSN) or the coding resistor is missing or does not match, for example after the board and the display were replaced at the same time. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.70?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.70

The meaning depends on the boiler: find yours below.

F.070

The appliance reference (DSN) is missing, incorrect or incompatible with the coding resistor.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.70

Appliance variant not valid for the display and/or the electronics

Breakdown: the boiler is stopped VCW /3, VUW /3-5
F.70

Fault §§ incorrect appliance coding

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7, VKK /4
F.70

Invalid appliance identification (DSN)

Breakdown: the boiler is stopped VC /4-5, VC 486/5-5, VC 806/5-5, VKK /5, VUW /4-5, VUW /5-5
F.70

Invalid appliance reference (DSN)

Breakdown: the boiler is stopped VCC /4
F.70

No valid DSN in AI and/or BMU

Breakdown: the boiler is stopped VSC /2

The boilers that show this code

What our technician checks

  • The device identification (DSN), to be set under d.93
  • The power-rating coding resistor
  • The wiring harness, between the board and the gas valve
  • The control electrode, to be replaced after the board and display were changed together

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.