Delayed gas valve shut-off
Breakdown: the boiler is stopped
After the burner stops, the boiler still sees a flame for too long: the gas valve closes late or leaks, or the electrode or the electronics are faulty; on the ecoTEC plus VC 486/5-5 and VC 656/5-5 this code reports a connection fault of the gas safety valve. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.62?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.62
The meaning depends on the boiler: find yours below.
The flame loss was detected with a delay.
Faulty gas valve shut-off delay
Fuel valve shut-off delay fault
Gas valve assembly shut-off delay
Gas safety valve connection fault
Gas valve assembly fault, shut-off delay
Gas valve shut-off delay faulty
Error in the gas valve shut-off delay
The boilers that show this code
What our technician checks
- The gas valve: closing and tightness, replaced if faulty
- The burner surface and injectors (dirt)
- The ignition and monitoring electrode (stray flame signal)
- The gas valve plug and wiring harness
- The connection between the circuit board and the gas safety valve
- The circuit board, replaced if faulty