Vaillant Fault code Vaillant
F.50

Flue gas pressure switch tripped

Breakdown: the boiler is stopped

On ecoVIT floor-standing boilers (VKK), the flue gas pressure switch has cut the burner: the flue or the condensate drain is blocked or badly laid (trap, neutraliser, pipe). This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.50?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.50

The meaning depends on the boiler: find yours below.

F.50

Flue gas pressure switch fault

Breakdown: the boiler is stopped VKK /4, VKK /5

What our technician checks

  • The condensate hose: length, kinks, fall, lift pump
  • The condensate neutraliser (dirt, blockage)
  • The flue gas collector and its drain hole
  • The burner: start pressure, pulsing
  • The flue: blockage, length, number of bends
  • The flue gas safety temperature limiter: cable and plug

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.