Air flow outside the allowed limits
Breakdown: the boiler is stopped
The combustion air flow measured by the boiler is outside the allowed limits: the fan, the air flow sensor, the wiring or a blocked flue can be the cause. The boiler goes into fault mode and stops until the cause is fixed and it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.342?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.342
The meaning depends on the boiler: find yours below.
The air mass flow is not within the permitted limits.
What our technician checks
- The fan speed (deviation of more than 20 to 30 rpm, D.033 and D.034)
- The connectors on the circuit board and on the air flow sensor
- The wiring harness and all its plugs
- The complete air intake tube, replaced if the sensor is faulty
- The whole flue system