Flame lost again during stabilisation

Breakdown: the boiler is stopped

The flame had gone out during operation and, when the burner relit, it went out again during the stabilisation time. The boiler goes into fault mode and stops until the cause is fixed and it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.291?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.291

The meaning depends on the boiler: find yours below.

F.291

The flame went out during the stabilisation period after a flame loss

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7

What our technician checks

  • The dynamic gas pressure and the external gas pressure switch
  • The gas type, its setting and the gas valve offset
  • The gas valve
  • The whole flue path and the air intake tube
  • The ignition, tested with test programme P.021
  • The control electrode and its wiring harness
  • The condensate drain, the trap and the combustion chamber
  • The condensate pump, if fitted

Related codes