Flame lost during stabilisation
Breakdown: the boiler is stopped
The flame went out during the stabilisation time after the burner lit. After five unsuccessful ignition attempts, the boiler goes into fault mode and stops until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the gas shut-off valve is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.281?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.281
The meaning depends on the boiler: find yours below.
The flame went out during the stabilisation time.
What our technician checks
- The gas supply pressure, the dynamic pressure and the external gas pressure switch
- The gas type, its setting and the gas valve offset
- The whole flue path and the air intake tube
- The ignition, tested with test programme P.021
- The control electrode and its wiring harness
- The gas valve and the burner
- The condensate drain, the trap and the combustion chamber
- The heat exchanger, the trap and the casing, for damage