Vaillant Fault code Vaillant
F.110

No ignition with the enriched mixture

Breakdown: the boiler is stopped

The boiler tried to light its burner with an enriched air-gas mixture and detected no successful ignition. The boiler goes into fault mode and stops until the cause is fixed and it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the gas shut-off valve is open.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.110?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.110

The meaning depends on the boiler: find yours below.

F.110

No successful ignition could be detected with the enriched air-gas mixture.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7

What our technician checks

  • The gas shut-off valve and the gas supply pressure
  • The dynamic gas pressure and the external gas pressure switch
  • The gas type, its setting and the gas valve offset
  • The ignition, tested with test programme P.021
  • The ignition electrode and transformer, with the harness and its plugs
  • The control electrode, its gap to the burner, and the earthing
  • The flue path, the air intake tube and the condensate drain
  • The burner, the gas valve and the circuit board

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.