No ignition with the enriched mixture
Breakdown: the boiler is stopped
The boiler tried to light its burner with an enriched air-gas mixture and detected no successful ignition. The boiler goes into fault mode and stops until the cause is fixed and it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the gas shut-off valve is open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.110?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.110
The meaning depends on the boiler: find yours below.
No successful ignition could be detected with the enriched air-gas mixture.
What our technician checks
- The gas shut-off valve and the gas supply pressure
- The dynamic gas pressure and the external gas pressure switch
- The gas type, its setting and the gas valve offset
- The ignition, tested with test programme P.021
- The ignition electrode and transformer, with the harness and its plugs
- The control electrode, its gap to the burner, and the earthing
- The flue path, the air intake tube and the condensate drain
- The burner, the gas valve and the circuit board