Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Junkers Fault code Junkers
F1

Internal data error

Breakdown: the boiler is stopped

The boiler's electronic control has found an error in its internal data; on a Cerapur ZWB-3 or a CerapurComfort ZWBR-3 the technician resets it to its base settings, which also clears the customised settings. It is a fault: the boiler stops and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F1?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F1

The meaning depends on the boiler: find yours below.

F1

Internal data error

Breakdown: the boiler is stopped Cerapur ZWB-3, Cerapur ZWBR-3, CerapurSmart

The boilers that show this code

What our technician checks

  • Resetting the Heatronic to its base settings (service function 8.E), on a Cerapur ZWB-3 or a CerapurComfort ZWBR-3
  • The installation's service settings, to be set again afterwards
  • On a CerapurSmart, the advice of the manufacturer's technical service

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.