Hot water cylinder sensor not detected
Breakdown: the boiler is stopped
The boiler does not detect the temperature sensor (NTC) of the hot water cylinder connected to it: the sensor or its cable is at fault, or the sensor was connected to a control module after the boiler had already detected it. It is a fault: the boiler stops and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show Ad?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code Ad
The meaning depends on the boiler: find yours below.
Cylinder NTC not detected / The NTC sensor is detected at the Heatronic 3 as…
Cylinder NTC not detected
Cylinder NTC sensor 1 not detected
Cylinder NTC 1 not detected
The boilers that show this code
What our technician checks
- The cylinder NTC sensor and its connecting cable
- Resetting the Heatronic 3 (function 8.E) and IPM 1 or IPM 2 to base settings, then the automatic system configuration on the thermostat (Cerapur ZWB-3, CerapurComfort ZWBR-3, CerapurSmart)