Junkers Fault code Junkers
CC

Outdoor temperature sensor not detected

Breakdown: the boiler is stopped

The boiler no longer detects its outdoor temperature sensor, the sensor outside used by the controls: the sensor, its cable or its connection is at fault. It is a fault: the boiler stops and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show CC?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code CC

The meaning depends on the boiler: find yours below.

CC

Outside temperature sensor not detected

Breakdown: the boiler is stopped Cerapur ZWB-3, Cerapur ZWBR-3, CerapurSmart
CC

Outside temperature NTC not detected

Breakdown: the boiler is stopped Cerapur, Cerasmart, ZWC-3

The boilers that show this code

What our technician checks

  • The outdoor sensor and its cable (break), replaced if needed
  • The sensor's connection to terminals A and F
  • The bus module, replaced if needed (CeraclassExcellence ZWC-3, Cerasmart, older Cerapur)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.