Heating temperature rising too fast
Breakdown: the boiler is stopped
The temperature of the heating water in the boiler rises too fast, a sign that the water is not circulating well: the circulating pump, the bypass, closed isolating valves or too low a water pressure is at fault. On a Cerapur ZWB-4 (D4 341) it is a blocking fault: the boiler stops for a while and starts again by itself; on a CeraclassExcellence ZWC-3 it stops and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure on the gauge, with the boiler cold: at least 1 bar. Too low? Top up as your installer showed you.
- Code D4 341 on a Cerapur ZWB-4: the boiler restarts by itself once the fault has cleared, do not reset it.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show D4?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code D4
The small number shown beside the code tells which.
CH temperature rising too fast
Gradient limitation: temperature rising too fast in heating mode
The boilers that show this code
What our technician checks
- The heating system's operating pressure
- The isolating valves, to be opened
- The circulating pump (service function t3), its cable and power setting, replaced if needed
- The bypass (CeraclassExcellence ZWC-3)