Return sensor or LSM module fault
Breakdown: the boiler is stopped
On a Eurostar ZWE-4, a Cerasmart or an older Cerapur, the LSM 5 module, which connects the safety device of an underfloor heating, has locked; on a CerapurComfort ZWBR-3, d1 points to a faulty return temperature sensor on the low loss header. It is a fault: the boiler stops and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show d1?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code d1
The meaning depends on the boiler: find yours below.
The return temperature sensor is faulty
LSM locked
The boilers that show this code
What our technician checks
- The wiring of the LSM 5 module
- The underfloor heating limiter, if it has tripped (older Cerapur)
- The low loss header return sensor and its cable (break, short circuit) (CerapurComfort ZWBR-3)