Daikin Fault code Daikin
U8

Connection problem with an accessory

Breakdown: the boiler is stopped

On a Daikin Altherma 3 heat pump (H HT, H MT, R, H or M), code U8 reports a connection problem between the user interface and a connected part, and the number shown next to it says which, depending on the model: 01 the LAN adapter for smartphone control, 02 and 03 the room thermostat, 04 an unknown USB device (software update), 05 a faulty file, 06 the bizone kit, 07 the P1P2 link, 09 a user interface software version that is not compatible with the indoor unit, 11 the wireless gateway; on an Altherma LT split or monobloc, U8-01 likewise reports the connection with the adapter lost. It is a fault for our technician to check, as Daikin leaves resetting an error code to an installer or the dealer; U8-04 can be reset after a successful software update.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show U8?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code U8

The small number shown beside the code tells which.

U8
01

Connection with LAN adapter lost

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
U8
02

Connection with room thermostat lost

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
U8
03

No connection with room thermostat

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
U8
04

Unknown USB device

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
U8
05

File malfunction

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
U8
06

MMI/bizone kit communication problem

Breakdown: the boiler is stopped Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
U8
07

P1P2 communication error

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
U8
09

MMI software version {version_MMI_software} /Indoor unit [version_IU_modelname]…

Breakdown: the boiler is stopped Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
U8
11

Connection with the Wireless gateway lost

Breakdown: the boiler is stopped Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R

What our technician checks

  • U8-01: the link with the LAN adapter
  • U8-02, U8-03: the link with the room thermostat
  • U8-04, U8-05: the USB device, in FAT32 format, its file and the software update
  • U8-06: the communication between the interface (MMI) and the bizone kit
  • U8-07: the P1P2 communication
  • U8-09: the compatibility of the interface (MMI) software version with the indoor unit
  • U8-11: the link with the wireless gateway

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.