Water circuit overheating
Breakdown: the boiler is stopped
The heating water temperature has risen too high: 8H-00, the water leaving the indoor unit (above 65 °C on the older Altherma EKHB/EKHV, where 8H shows alone); 8H-01 and 8H-02, the mixed water circuit (on the Altherma 3 H HT and 3 R, 8H-01 also covers water that is too cold); 8H-03, overheating of the water circuit detected by the thermostat; 8H-08, the water circuit of the ECH2O models. It is an error code that an installer must reset after finding the cause, except 8H-01 and 8H-02 on a bizone Altherma low temperature (EHVZ): they clear by themselves and the screen refers to the bizone kit manual.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 8H?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 8H
The small number shown beside the code tells which.
Outlet water temperature of indoor unit too high (>65°C)
Abnormal increase outlet water temperature
Overheating mixed water circuit
Overheating mixed water circuit (thermostat)
Overheating water circuit (thermostat)
Overheating water circuit
What our technician checks
- The electric backup heater contactor: not short-circuited
- The outlet water thermistor, which must give a correct reading
- The bizone kit, following its manual (8H-01, 8H-02 on a bizone Altherma low temperature)
- The detailed troubleshooting of this code in the Daikin service manual