Water temperature sensor problem
Breakdown: the boiler is stopped
The heat pump no longer gets a correct reading from one of its water temperature sensors: 81-00 (81 alone on the older Altherma EKHB/EKHV), the flow sensor to the heating; 81-01, the mixed water sensor; 81-06, the indoor unit's inlet water sensor; 81-07, on an Altherma 3 ECH2O, the mixed flow water sensor after the tank (DLWA2). It is an error code that an installer must reset after finding the cause, except 81-01 on a bizone Altherma low temperature (EHVZ): it clears by itself and the screen refers to the bizone kit manual.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 81?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 81
The small number shown beside the code tells which.
Outlet water temperature thermistor failure (outlet water temperature sensor broken)
Leaving water temperature sensor problem
Mixed water thermistor abnormality
Entering water temperature thermistor abnormality (indoor unit)
Mixed leaving water temperature after the tank thermistor abnormality (DLWA2)
What our technician checks
- The sensor named by the sub-code: flow (81-00), mixed water (81-01), indoor unit water inlet (81-06), mixed flow after the tank DLWA2 (81-07)
- The sensor's connections and wiring (loose connections, faulty cables)
- The bizone kit, following its manual (81-01 on a bizone Altherma low temperature)
- The detailed troubleshooting of this code in the Daikin service manual