Water too hot while heating hot water
Breakdown: the boiler is stopped
While heating domestic hot water, the temperature of the water leaving the indoor unit has risen abnormally (above 75 °C on the older Altherma EKHB/EKHV). It is an error code: it stays on until an installer has found the cause and reset it.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 8F?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 8F
The small number shown beside the code tells which.
Outlet water temperature of indoor unit too high (>75°C) during domestic water heating
Abnormal increase outlet water temperature (DHW)
What our technician checks
- The electric backup heater contactor: not short-circuited
- The outlet water thermistor, which must give a correct reading
- The detailed troubleshooting of this code in the Daikin service manual