Heat exchanger freeze protection activated
Breakdown: the boiler is stopped
The heat pump has detected a risk of freezing in its water heat exchanger, during defrost (89-01, 89-03), heating or hot water (89-02) or cooling (89-05, 89-06), for example because too little water flows through it; on the Altherma low temperature units 89-01 to 89-03 report a frozen heat exchanger, and on the older Altherma EKHB/EKHV code 89 can also come from a lack of refrigerant. On an Altherma 3, Daikin marks 89-02, 89-03 and 89-06 as warnings and 89-01 and 89-05 as errors; an error stays on until an installer has found the cause and reset it.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 89?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 89
The small number shown beside the code tells which.
Water heat exchanger freeze-up failure (due to water flow too low) / Water heat exchanger freeze-up failure (due to refrigerant shortage)
Heat exchanger freeze-up protection activated during defrost (error)
Heat exchanger freeze-up protection activated during heating / DHW operation
Heat exchanger freeze-up protection activated during defrost (warning)
Heat exchanger freeze-up protection activated during cooling operation
Heat exchanger freeze-up protection activated during cooling operation
What our technician checks
- The water flow, as for code 7H: valves, filter, air, pressure
- The minimum water volume of the system when cooling (89-05, 89-06)
- The refrigerant charge: lack of refrigerant
- The detailed troubleshooting of this code in the Daikin service manual