Daikin Fault code Daikin
89

Heat exchanger freeze protection activated

Breakdown: the boiler is stopped

The heat pump has detected a risk of freezing in its water heat exchanger, during defrost (89-01, 89-03), heating or hot water (89-02) or cooling (89-05, 89-06), for example because too little water flows through it; on the Altherma low temperature units 89-01 to 89-03 report a frozen heat exchanger, and on the older Altherma EKHB/EKHV code 89 can also come from a lack of refrigerant. On an Altherma 3, Daikin marks 89-02, 89-03 and 89-06 as warnings and 89-01 and 89-05 as errors; an error stays on until an installer has found the cause and reset it.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 89?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 89

The small number shown beside the code tells which.

89

Water heat exchanger freeze-up failure (due to water flow too low) / Water heat exchanger freeze-up failure (due to refrigerant shortage)

Breakdown: the boiler is stopped Altherma LT EKHB/EKHV
89
01

Heat exchanger freeze-up protection activated during defrost (error)

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
89
02

Heat exchanger freeze-up protection activated during heating / DHW operation

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
89
03

Heat exchanger freeze-up protection activated during defrost (warning)

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
89
05

Heat exchanger freeze-up protection activated during cooling operation

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
89
06

Heat exchanger freeze-up protection activated during cooling operation

Blocking: it retries by itself Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R

What our technician checks

  • The water flow, as for code 7H: valves, filter, air, pressure
  • The minimum water volume of the system when cooling (89-05, 89-06)
  • The refrigerant charge: lack of refrigerant
  • The detailed troubleshooting of this code in the Daikin service manual

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.