Power supply or circuit board fault
Breakdown: the boiler is stopped
The meaning depends on the heat pump: on an Altherma 3 and an Altherma low temperature, A1-00 means it does not correctly detect the zero crossing of the supply voltage (unstable frequency); A1-01 (Altherma low temperature) is an EEPROM memory read error, and on the older Altherma EKHB/EKHV and the Altherma HT, A1 reports a faulty indoor circuit board or a memory write error. It is an error code that our technician has to solve; on an Altherma low temperature the screen also shows "Power reset required" and "Please contact your dealer".
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show A1?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code A1
The small number shown beside the code tells which.
Indoor unit PCB defective
Failure of writing memory (EEPROM error)
Zero cross detection problem
EEPROM reading error
What our technician checks
- The unit's power supply: voltage and frequency stability (A1-00)
- The indoor unit circuit board and its EEPROM memory (A1-01, A1 on older units)
- The connections and wiring (loose connections, faulty cables)