Backup heater overheated
Breakdown: the boiler is stopped
The thermal protection of the electric backup heater has tripped or, on an Altherma 3 (AA-01), its power cable is not connected; AA-02 (Altherma 3 R and 3 H) concerns an external backup heater, and on an Altherma HT code AA concerns the optional heater kit, also when it is connected to the reduced rate power supply. It is an error code: an installer must find the cause, check the water circuit and reset the protection, whose button is in the switch box.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show AA?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code AA
The small number shown beside the code tells which.
Backup heater thermal protector is open / Check the reset button of the thermal protector
Heater kit thermal cut out error (if the heater kit option installed) / Heater kit connected to the benefit kWh rate power supply
Backup heater overheated or BUH power cable not connected
External backup heater overheated
What our technician checks
- The backup heater thermal protector, reset with the button in the switch box after checking
- The water pressure, air in the circuit and the air purge
- The water flow: all valves of the circuit open
- The backup heater power cable, properly connected (AA-01)
- The backup heater thermal fuse, if it has blown
- The external backup heater (AA-02)
- The heater kit of an Altherma HT: connected to the normal power supply, not the reduced rate