Screed drying not completed
Breakdown: the boiler is stopped
The underfloor heating screed drying programme, which the installer starts at commissioning, stopped before the end: because of another error or a stop, and also because of a power cut on an Altherma 3 H, an Altherma low temperature split or monobloc or an older Altherma EKHBH/EKHBX or EKHVH/EKHVX indoor unit (on an Altherma 3 H HT, 3 H MT, 3 R or 3 M, a power cut does not give U3: the programme resumes by itself when the power returns). The code stays on until our technician resets it and restarts the drying.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show U3?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code U3
The small number shown beside the code tells which.
Underfloor heating screed dry-out program has been stopped by another error, or by…
Underfloor heating screed dryout function not completed correctly
What our technician checks
- Why the drying stopped: another error code, a manual stop or a power cut
- The screed drying status (step where it stopped), then restarting the programme
- Resetting U3 at the Installer user permission level (Altherma low temperature)
- Resetting U3 in test mode, then setting [F-08] again for a new drying run (EKHBH/EKHBX, EKHVH/EKHVX)