Daikin Fault code Daikin
J6

Malfunction of heat exchanger thermistor

Breakdown: the boiler is stopped

On a Daikin Altherma 3 H HT, 3 H MT, 3 R, 3 H or 3 M heat pump, or an Altherma low temperature split, monobloc or EKHB/EKHV, code J6 (J6-00, J6-07) reports a fault of the heat exchanger thermistor of the outdoor unit, the air coil thermistor (frost detection) on the EKHB/EKHV; the other sub-codes concern other sensors: J6-32 the leaving water thermistor of the outdoor unit and J6-33 a sensor communication error (Altherma 3 H HT, 3 H MT, 3 H and 3 M), J6-36 the injection thermistor (Altherma 3 H MT). This is a fault, not just information: our technician must find its cause before resetting it, which Daikin reserves for an approved installer.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show J6?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code J6

The small number shown beside the code tells which.

J6

Aircoil thermistor frost detection failure

Breakdown: the boiler is stopped Altherma LT EKHB/EKHV
J6
00

OU: Malfunction of heat exchanger thermistor

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
J6
07

OU: Malfunction of heat exchanger thermistor

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R
J6
32

Leaving water temperature thermistor Abnormality (outdoor unit)

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M
J6
33

Sensor communication error

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M
J6
36

OU: Malfunction of injection thermistor

Breakdown: the boiler is stopped Altherma 3 H MT

What our technician checks

  • The heat exchanger thermistor of the outdoor unit (J6-00, J6-07)
  • The leaving water thermistor of the outdoor unit (J6-32)
  • The communication with the sensors (J6-33)
  • The injection thermistor (J6-36, Altherma 3 H MT)
  • EKHB/EKHV: the air coil thermistor and its frost detection
  • Thermistors and pressure sensors in place: never run without them (risk to the compressor)
  • The detailed troubleshooting for this code in Daikin's service manual

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.