Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Daikin Fault code Daikin
C0

Flow sensor or flow switch fault

Breakdown: the boiler is stopped

The heat pump monitors the water flow with a flow sensor and a flow switch; code C0 appears when one of them is faulty or detects flow while the circulation pump is stopped, for example because another device is making the water circulate. With C0-00 (flow sensor) and C0-02 (flow switch, persistent problem) the heat pump stops until our technician resets the code; with C0-01 (flow switch) it stops for a while and then restarts by itself. On the Altherma LT EKHB/EKHV, code C0 (without a sub-code) reports a flow switch that stays closed while the circulation pump is stopped.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show C0?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code C0

The small number shown beside the code tells which.

C0

Flow switch failure (flow switch remains closed while pump is stopped)

Breakdown: the boiler is stopped Altherma LT EKHB/EKHV
C0
00

Flow sensor malfunction

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc, Altherma LT split
C0
01

Flow switch malfunction

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc
C0
02

Flow sensor malfunction

Breakdown: the boiler is stopped Altherma 3 H, Altherma 3 H HT, Altherma 3 H MT, Altherma 3 M, Altherma 3 R, Altherma LT monobloc

What our technician checks

  • An external device causing flow while the circulation pump is stopped
  • The flow sensor and the flow switch
  • The flow switch, which must not be clogged with dirt (Altherma LT EKHB/EKHV)
  • Resetting C0-00 and C0-02 by the technician, once the cause is fixed
  • The detailed procedure for this code in the Daikin service manual

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.