Hot water tank disinfection not completed
Breakdown: the boiler is stopped
The periodic disinfection of the hot water tank (anti-legionella) did not finish correctly, for example because a lot of hot water was drawn just before or during it, because hot water production was switched off during the disinfection or, on an Altherma 3 H, 3 M or low temperature monobloc, because the tank's booster heater was cut out by its safety thermostat. Daikin lists it among the error codes: it stays on until an installer resets it, and our technician can move the disinfection start time, which is set in the installer settings.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show AH?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code AH
The small number shown beside the code tells which.
Tank disinfection function not completed correctly
What our technician checks
- The disinfection start time, at least 4 hours after the last expected large hot water draw
- In schedule only mode, an Eco action programmed 3 hours before the disinfection
- Tank operation left on during the disinfection
- The tank booster heater and its safety thermostat