Waiting time after flame loss
Blocking: it retries by itself
The burner flame went out during operation: the boiler observes a waiting time before trying to relight. It is not a locked fault, but repeated flame losses must be checked: they can come from the gas supply.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show S.60?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code S.60
The meaning depends on the boiler: find yours below.
Waiting time following flame loss during burner operation
Waiting time after flame loss
What our technician checks
- The dynamic gas pressure
- The gas valve and the gas meter
- The thermal shut-off device
- The cable connections and the ignition system
- The monitoring electrode
- The appliance earthing
- The air/gas ratio