Gas valve at its lower control limit
Breakdown: the boiler is stopped
The motor that sets the gas valve opening has reached the end of its range, on the minimum side. The appliance switches to emergency mode, with reduced comfort, and the code does not clear by itself: our technician has to step in.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show N.095?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code N.095
The meaning depends on the boiler: find yours below.
The gas valve stepper motor has reached the minimum permissible number of steps
What our technician checks
- The whole flue gas path (recirculation, blockage)
- The condensate drain pipe
- The gas type and its setting
- The gas valve offset setting (D.052)
- The wiring harness and electrical connection of the gas valve
- The control electrode, replaced if needed
- The circuit board, to be replaced if faulty