Weak flame signal or spillage sensor fault
Breakdown: the boiler is stopped
On the Thema Condens and IsoTwin Condens CS/1 (F.044), the boiler does not get enough signal from its flame electrode to control its combustion: recirculating flue gas, blocked condensate drain, gas pressure or type, electrode or gas valve. On the older Isotwin (F44), it is the internal flue sensor of the spillage safety device (TTB) that is disconnected or short-circuited; in both cases a technician is needed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.044?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.044
The meaning depends on the boiler: find yours below.
The control electrode ionisation signal is insufficient
Internal temperature sensor for TTB safety device
The boilers that show this code
What our technician checks
- The flue along its whole length
- The condensate drain
- The dynamic gas pressure, the gas type and its setting
- The control electrode
- The gas valve and the circuit board
- The wiring harness
- Isotwin: the internal flue sensor connections