Bulex Fault code Bulex
F.040

Air ratio too low

Breakdown: the boiler is stopped

On the Thema Condens and IsoTwin Condens CS/1, the boiler can no longer control its air and gas mixture properly: blocked flue, blocked condensate drain, wrong gas type or pressure, gas valve, electrode or fan at fault. It is a fault: the boiler stops until a technician has been.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.040?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.040

The meaning depends on the boiler: find yours below.

F.040

The air ratio is insufficient

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1

What our technician checks

  • The flue along its whole length
  • The condensate drain
  • The dynamic gas pressure, the gas type and its setting
  • The gas valve offset setting
  • The gas valve harness and electrical connection
  • The control electrode and the circuit board
  • The fan