Bulex Fault code Bulex
N.027

Hot water temperature sensor signal implausible

Breakdown: the boiler is stopped

The signal of the temperature sensor on the domestic hot water connection is not plausible. The appliance switches to emergency mode, with reduced comfort, and the code does not clear by itself: our technician has to step in.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show N.027?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code N.027

The meaning depends on the boiler: find yours below.

N.027

The hot water connection temperature sensor signal is not plausible

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1

What our technician checks

  • The temperature sensor, replaced if needed
  • The wiring harness
  • The diverter valve stepper motor and its wiring
  • Scale in the secondary heat exchanger
  • How the hot water sensor is mounted on the pipe
  • The cold water adjusting valve: fitted and set right (boilers without a factory flow limiter)

Related codes