Flame signal too weak at the control electrode
Breakdown: the boiler is stopped
The flame signal measured by the control electrode is too weak, and the boiler has failed several times to make up for the wear of this electrode. The appliance switches to emergency mode, with reduced comfort, and the code does not clear by itself: our technician has to step in.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show N.144?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code N.144
The meaning depends on the boiler: find yours below.
The control electrode ionisation signal is insufficient
What our technician checks
- The whole flue gas path (recirculation, blockage)
- The condensate drain pipe
- The dynamic gas pressure (and the external gas pressure switch, if any)
- The gas type and its setting
- The control electrode, replaced if needed
- The gas valve, to be replaced if faulty
- The circuit board, to be replaced if faulty
- The wiring harness and all its connectors