Bulex Fault code Bulex
L.320

Heating pump blocked

Blocking: it retries by itself

The heating pump is blocked and the boiler is trying to free it by itself. The appliance switches to emergency mode, with reduced comfort, and the code clears by itself as soon as the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show L.320?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L.320

The meaning depends on the boiler: find yours below.

L.320

The heating pump is blocked. The appliance is attempting to clear the blockage

Blocking: it retries by itself Isotwin Condens CS/1, Thema Condens CS/1

What our technician checks

  • The pump: dirt or a foreign body, to be cleaned or changed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.