Gas valve at its minimum limit

Breakdown: the boiler is stopped

The motor of the gas valve, which meters gas to the burner, has reached the lower limit of its adjustment, which points to a problem in the flue path, the condensate drain, the gas setting or a component. The boiler goes into fault mode and stops until the cause is fixed and it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.095?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.095

The meaning depends on the boiler: find yours below.

F.095

The gas valve stepper motor has reached the minimum permissible number of steps

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1

What our technician checks

  • The whole flue gas path (recirculation, blockage)
  • The condensate drain pipe
  • The gas type and its setting
  • The gas valve offset setting
  • The gas valve, its connection and its wiring harness
  • The control (ionisation) electrode and the circuit board, replaced if needed

Related codes