Overheating or flue gas sensor fault
Breakdown: the boiler is stopped
On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30, Isotwin and Isomax (F5 without a dot), it is overheating: the water in the boiler got too hot, for example for lack of circulation, and the safety device stopped the boiler. On the ThemaClassic C30 and the ThemaTek C 18/24-LC/1 (F.05), the outer flue gas sensor is disconnected; in both cases the boiler stays off until a technician has been.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset and do not take anything apart: call us.
Does your boiler show F5?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F5
The meaning depends on the boiler: find yours below.
NTC sensor open circuit (external flue gas temperature sensor)
PTC sensor open circuit (external flue gas temperature sensor)
Overheating fault
Manual reset: maximum fault, flow temperature too high
Overheating protection
The boilers that show this code
What our technician checks
- Older boilers: the pump
- Older boilers: the flow and return isolating valves being open
- Older boilers: the radiators open and bled
- ThermoMaster HR TOP: the flow sensor, its position and the pump cable
- ThemaClassic C30, ThemaTek: the outer flue gas sensor and its connector
- ThemaClassic C30, ThemaTek: the appliance reference setting, the harness and the multi-pin connector