Flame detection or flow sensor fault
Breakdown: the boiler is stopped
On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30 and Isotwin (F16 without a dot), the boiler does not sense its flame properly (abnormal flame, ionisation electrode disconnected or out of adjustment, poor earth) and goes into safety mode. On the ThemaClassic C30 and the ThemaTek C 18/24-LC/1 (F.16), the water flow sensor is short-circuited; in both cases a technician is needed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F16?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F16
The meaning depends on the boiler: find yours below.
Flow sensor short circuit
Flame detection fault
No flame after 5 seconds, flame present
The boilers that show this code
What our technician checks
- Older boilers: the flame-sensing electrode
- Older boilers: the main board and the gas valve
- ThermoMaster F: the CO2 setting
- ThermoMaster HR TOP: all the earth wiring
- ThemaClassic C30, ThemaTek: the flow sensor and the wiring harness