Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bulex Fault code Bulex
F.346

Hard ignition detected, ignition failed

Breakdown: the boiler is stopped

The boiler detected a hard ignition of the burner, and the ignition failed. The boiler goes into fault mode and stops until the cause is fixed and it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.346?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.346

The meaning depends on the boiler: find yours below.

F.346

A "hard" ignition has been detected. Ignition failed

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1

What our technician checks

  • The whole flue path and the air intake tube
  • The gas valve offset setting and the replacement gas valve
  • The connectors (circuit board, ignition transformer) and the wiring harness
  • The ignition electrode, to be replaced
  • The control electrode, its cable and its plug
  • The earthing of the appliance
  • The circuit board
  • The heat exchanger, the trap and the casing, for damage

Related codes