Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bulex Fault code Bulex
F.344

Control electrode unusable

Breakdown: the boiler is stopped

The boiler cannot use its control electrode: an error occurred when its calibration values were transferred. The boiler goes into fault mode and stops until the cause is fixed and it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.344?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.344

The meaning depends on the boiler: find yours below.

F.344

The control electrode is unusable

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1

What our technician checks

  • The control electrode, to be replaced

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.