No flame detected
Breakdown: the boiler is stopped
The boiler does not detect a flame at its burner (no ionisation): the gas is not coming through, or the ignition, an electrode or the flue is at fault; on a Condens 7000iW, EA 261 rather points to a timing fault of the control unit. It is a fault: the boiler stops and only starts again after a reset; on a Condens 7000iW (EA 227, EA 229) it first makes new ignition attempts by itself and only locks out after the fourth.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Code EA 229 on a Condens 7000iW: the boiler restarts by itself once the fault has cleared, do not reset it.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show EA?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code EA
The small number shown beside the code tells which.
Flame not detected (no ionisation)
Flame not detected
No ionisation signal during burner operation
Timing fault during the first safety time
The boilers that show this code
What our technician checks
- The gas tap and the gas supply pressure
- The mains connection, the earthing and the coding plug
- The ignition and ionisation electrodes and their cables, replaced if needed
- The flue and the combustion air supply
- The burner's gas/air ratio (CO2)
- The condensate trap, the fan membrane and the heat exchanger, cleaned
- The gas valve and, on natural gas, the external gas flow monitor (Condens 7000iW), replaced if needed
- For EA 261: the connectors and wiring to the control unit, then the control unit itself