Flame lost while the burner was running
Blocking: it retries by itself
The burner flame went out while the boiler was running; the gas supply (tap, pressure), the ionisation electrode, the ignition or the flue may be the cause. It is a blocking fault: the boiler stops for a while and restarts by itself once the fault has gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 229?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 229
The meaning depends on the boiler: find yours below.
Flame went out during burner operation
The boilers that show this code
What our technician checks
- The main gas valve and the boiler's gas tap, open
- The gas pressure at rated load and the gas pipe
- The ionisation electrode, its cable and the ionisation current
- The earth terminal in the control unit and the ignition cable
- The gas valve's safety valves, by measuring their resistance
- The burner setting at rated load and at minimum output
- The flue and the combustion air supply
- Deposits on the flue side of the heat exchanger and the contact wire on the burner cover