Bosch Fault code Bosch
229

Flame lost while the burner was running

Blocking: it retries by itself

The burner flame went out while the boiler was running; the gas supply (tap, pressure), the ionisation electrode, the ignition or the flue may be the cause. It is a blocking fault: the boiler stops for a while and restarts by itself once the fault has gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 229?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 229

The meaning depends on the boiler: find yours below.

229

Flame went out during burner operation

Blocking: it retries by itself GC2300iW

The boilers that show this code

What our technician checks

  • The main gas valve and the boiler's gas tap, open
  • The gas pressure at rated load and the gas pipe
  • The ionisation electrode, its cable and the ionisation current
  • The earth terminal in the control unit and the ignition cable
  • The gas valve's safety valves, by measuring their resistance
  • The burner setting at rated load and at minimum output
  • The flue and the combustion air supply
  • Deposits on the flue side of the heat exchanger and the contact wire on the burner cover