Internal boiler fault

Breakdown: the boiler is stopped

The boiler's electronic control reports an internal fault, linked to a connection, an ignition lead, the circuit board or the gas/air setting; on a Condens 7000iW the number next to it gives the cause, for example F0 238 for the gas valve or its cable and F0 356 for an interrupted mains voltage. It is a fault: the boiler stops and only starts again after a reset; only F0 356 clears by itself once the power is back.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Code F0 356 on a Condens 7000iW: the boiler restarts by itself once the fault has cleared, do not reset it.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F0?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F0

The small number shown beside the code tells which.

F0

Internal error

Breakdown: the boiler is stopped Condens 3000 W
F0
238

Gas valve connecting cable, gas valve or control unit faulty

Breakdown: the boiler is stopped GC7000iW
F0
239

Internal fault

Breakdown: the boiler is stopped GC7000iW
F0
259

Internal fault

Breakdown: the boiler is stopped GC7000iW
F0
280

Timing error during the restart attempt

Breakdown: the boiler is stopped GC7000iW
F0
290

Internal fault

Blocking: it retries by itself GC7000iW
F0
356

Mains voltage interrupted

Blocking: it retries by itself GC7000iW

The boilers that show this code

What our technician checks

  • The electrical plugs and connectors, the wiring and the ignition leads
  • The burner's gas/air ratio (CO2)
  • For F0 238: the gas valve wiring and the gas valve, replaced if needed
  • For F0 239 and F0 259: the coding plug, replaced
  • For F0 356: the mains voltage
  • The circuit board or the control unit, replaced if needed

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

Related codes