The boiler detects no flame
Breakdown: the boiler is stopped
The boiler tries to light its burner but detects no flame: the gas (closed tap, pressure), the ignition, the electrodes or the flue may be the cause. The boiler makes further ignition attempts by itself; after the fifth, the fault becomes a locking fault and the boiler only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 227?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 227
The meaning depends on the boiler: find yours below.
Flame not detected
The boilers that show this code
What our technician checks
- The gas tap, open
- The gas supply pressure
- The ionisation signal and the mains connection
- The electrodes and their cables, replaced if needed
- The flue system, cleaned or repaired
- The air-gas ratio and the burner setting
- Cleaning the heat exchanger
- The gas valve, replaced if needed