Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
ACV Fault code ACV
E79

Mixing circuit sensor open circuit

Breakdown: the boiler is stopped

The circuit of the temperature sensor of the heating circuit with the mixing valve is open: the sensor or its cable is broken or disconnected. It is a fault: the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E79?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E79

The meaning depends on the boiler: find yours below.

E79

Mixing valve sensor circuit open

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • The mixing valve sensor and its wiring (open circuit)
  • The sensor or its wiring, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.