ACV Fault code ACV
E34

Mains power supply problem

Breakdown: the boiler is stopped

On the Prestige MkIII and HeatMaster 25 C with the ESYS controller, E34 means the mains frequency deviates by more than 1.5 Hz: it is a fault, the boiler locks out and only starts again after a reset. On boilers with the ACVMax or ACVMax Touch controller (Prestige from 2014, HeatMaster TC from 2015, HeatMaster Evo, WaterMaster), E34 means the mains voltage is too low: the boiler waits and starts again by itself once the voltage is back.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. On a boiler with the ACVMax or ACVMax Touch controller, it starts again by itself once the voltage is back: do not reset it.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E34?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E34

The meaning depends on the boiler: find yours below.

E34

Mains frequency deviation > 1.5 Hz

Breakdown: the boiler is stopped ESYS
E34

Low voltage

Blocking: it retries by itself ACVMax, ACVMax Touch

What our technician checks

  • The mains frequency (ESYS)
  • The mains voltage (ACVMax, ACVMax Touch)