Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
ACV Fault code ACV
E21

Internal control board error

Breakdown: the boiler is stopped

The boiler's control board has detected an internal error in converting its readings (analogue-to-digital converter). It is a fault: the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E21?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E21

The meaning depends on the boiler: find yours below.

E21

ADC error

Breakdown: the boiler is stopped ESYS
E21

Internal control error

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • Switching the appliance off and on, then a reset (ACVMax: OK key)
  • The ESYS control board, replaced if needed (ESYS)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.