Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
F4

The boiler detects no flame

Breakdown: the boiler is stopped

The boiler does not detect the flame of its burner: the ignition, the gas supply or gas pressure, the gas valve, the electrode that monitors the flame or, on a Vitodens, the condensate drain may be the cause. It is a fault: for safety the burner locks out and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F4?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F4

The meaning depends on the boiler: find yours below.

F4

No flame signal

Breakdown: the boiler is stopped Vitodens 100-W B1HC
F4

Flame signal absent

Breakdown: the boiler is stopped Vitodens 100-W B1HA, Vitodens 100-W WB1A, Vitodens 100-W WB1B, Vitodens 100-W WB1C, Vitodens 200 WB2A, Vitodens 222-W WS2A, Vitopend 100-W A1JA, Vitopend 100-W WH1D

What our technician checks

  • The ignition and ionisation electrodes and their connecting cable
  • The ionisation current, measured (Vitodens 222-W WS2A, 200 WB2A)
  • The gas pressure and the combined gas valve
  • The ignition and the igniter
  • The condensate drain (Vitodens)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.