LON communication module fault
Blocking: it retries by itself
On the Vitodens 200, 222 and 300 and the Vitotronic 200 KO1B, the control no longer communicates with its communication module (LON), the board that links it to other controls (Vitotronic 200-H) or to the Vitocom, and on the Vitotronic 300 KW3 the same code reports a lost link with an extension module of the Viessmann two-wire bus. The boiler keeps running: only the link with those other devices is affected.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show CF?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code CF
The meaning depends on the boiler: find yours below.
Communication fault of the communication module
Communication fault with the LON communication module
Communication error with the LON communication module
Communication fault of the LON module of the control unit
Communication fault Viessmann two-wire BUS extension module
What our technician checks
- The LON communication module, replaced if needed
- Without a LON module: coding 76 set to 76:0 (Vitodens 222-F B2SB, B2TA, B2SA, Vitotronic 200 KO1B)
- On the Vitotronic 300 KW3: the two-wire bus extension module and its connecting cable