Circuit 2 mixing valve: connection lost
Blocking: it retries by itself
The controller no longer communicates with the mixing valve extension kit of heating circuit 2 (mixing circuit M1 on a Vitotronic 300 KW3). The boiler keeps running, but the mixing valve of that circuit holds the flow temperature at only 20 °C (on a Vitodens 222-W WS2A it closes, on a Vitotronic 200 KO1B or 300 KW3 it keeps regulating).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show bA?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code bA
The meaning depends on the boiler: find yours below.
Communication fault of the motor drive for heating circuit 2 (with mixing valve)
Communication error with the mixing valve motor for heating circuit M2
Communication error of the motorisation equipment for heating circuit 2 (with mixing valve)
Communication fault of the mixing valve motor equipment
Faulty communication of the actuator for the circuit with mixing valve M1
Communication error of the actuator for heating circuit M2
What our technician checks
- The connections of the mixing valve extension kit
- The coding or assignment of the extension kit (rotary switch on a Vitotronic 200 KO1B)
- Switching the extension kit on (Vitodens 200-W WB2B, 200 WB2A, 222-W WS2A)