Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
S.53

Waiting time due to water shortage

Blocking: it retries by itself

The boiler measures too large a gap between the water leaving for the heating and the water coming back, a sign of water shortage: it limits its power or blocks the burner for a waiting time. It then restarts by itself, but if the code comes back, the water pressure of the system must be checked.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure (display or gauge): below 0.8 bar, top up the heating water as your installer showed you.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show S.53?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code S.53

The meaning depends on the boiler: find yours below.

S.53

The appliance is in the modulation lockout time/the service lockout function time of

Blocking: it retries by itself VCW /3
S.53

Waiting time Lack of water

Blocking: it retries by itself VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7
S.53

Product waiting for modulation lockout/safety shutdown function due to

Blocking: it retries by itself VC /4-5, VC 806/5-5, VUW /5-5
S.53

Modulation blocked by the safety function due to lack of water

Blocking: it retries by itself VC 486/5-5
S.53

The appliance is in a pause for 2.5 minutes due to a lack

Blocking: it retries by itself VUW /3-5
S.53

Product in a 2.5-minute waiting period due to lack of water (difference

Blocking: it retries by itself VUW /4-5
S.53

Appliance waiting for modulation block/operation lock function

Blocking: it retries by itself VCC /4
S.53

The appliance is in a pause for 20 minutes due to lack of water

Blocking: it retries by itself VSC /2

The boilers that show this code

What our technician checks

  • The water pressure and filling of the system
  • Air in the system, to be purged
  • The heating pump, its cable and connector
  • The flow and return sensors, not swapped
  • The strainer of the hydraulic block

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.