Hot gas thermostat tripped
Blocking: it retries by itself
On a Vaillant aroTHERM Split (VWL ../5 AS), aroTHERM plus (VWL ../6 A), versoTHERM plus or recoCOMPACT exclusive heat pump, the refrigerant is too hot at the compressor outlet and the hot gas thermostat switches the heat pump off; it stays off for an hour, then restarts. If the temperature has not dropped after the third failed attempt, the heat pump switches off and shows fault F.823.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show S.286?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.